EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
26.10.2026
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Brachialis
Literature
- Position
- In the distal third of the upper arm where the muscle becomes superficial - two to three fingerbreadths lateral to the line from acromion to cubital fossa, clear of biceps and triceps
- Orientation
- Along the muscle fibres, 2 cm inter-electrode distance
- MVC test
- Seated or kneeling in front of a bench, elbow at about 90°, forearm supinated.
- Fixation
- Very stable fixation of elbow and trunk; the upper arm stays vertical at the side.
- Resistance
- Rigid resistance under the wrist (strap to the floor, bar or manual), elbow flexion against it.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: Date et al. 2021 · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=brachialis_l