EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
25.09.2026
25.09.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance 5–50 kΩ, aim low · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Triceps Brachii Caput Longum
SENIAM
- Position
- 50% on line between posterior crest of the acromion and olecranon, 2 finger widths medial to the line
- Orientation
- Parallel to line posterior crest of the acromion–olecranon
- Signal check
- Extend the forearm against resistance.
- Crosstalk from
- biceps brachii · posterior and middle deltoid
- MVC test
- Same set-up as the biceps test: seated or kneeling, elbow at about 90°, upper arm slightly abducted.
- Fixation
- Elbow and trunk fixed as for the biceps.
- Resistance
- Rigid resistance from above on the wrist (fixed bar or manual), elbow extension against it.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: SENIAM (Hermens 2000) · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=triceps_brachii_long_l
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer