EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
25.10.2026
25.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Trapezius Pars Ascendens
SENIAM
- Position
- 2/3 on line from trigonum spinae to T8
- Orientation
- Along the line T8–acromion
- Signal check
- Abduct the arms; retract the shoulder back and down at 45°.
- Crosstalk from
- middle trapezius · rhomboids · erector spinae
- MVC test
- Simulated pull-up: elbows at about 90° flexion, check a frontal and a lateral arm position.
- Fixation
- Fixed bar or machine; trunk stabilised.
- Resistance
- Pulling against the fixed bar.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: SENIAM (Hermens 2000) · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=trapezius_ascendens_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer