EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
26.10.2026
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Sartorius
Literature
- Position
- Proximal anterior thigh, approx. 4 cm distal to the anterior superior iliac spine; stay proximal to minimise crosstalk from the rectus femoris
- Orientation
- Oblique along the muscle course (from the ASIS medially and distally), 2 cm inter-electrode distance
- Signal check
- Supine: flex and externally rotate the thigh while flexing the knee.
- Crosstalk from
- rectus femoris · iliopsoas · adductor magnus
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=sartorius_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer