Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance 5–50 kΩ, aim low · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Rectus Abdominis
Literature
- Position
- 4cm lateral to the midline, at the level of the navel
- Orientation
- Parallel to the muscle (vertical)
- MVC test
- Supine, knees bent, sit-up style: flex the spine by about 30° and hold that position.
- Fixation
- Very good leg fixation is essential; hold the 30° position with a belt or manually.
- Resistance
- Belt or manual resistance against the chest, trunk flexion against it.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: Ng et al. 1998 · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005