EMG session sheet

Electrode positions, signal check and MVC test on one sheet

emgguide.de
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate

Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter

S1 M. Multifidus Multifidus · left · Trunk Posterior SENIAM
Position on the 3D model:
emgguide.de/?muscle=multifidus_l
Position
On the line from the caudal tip of the posterior superior iliac spine to the L1/L2 interspace, at the level of the L5 spinous process - about 2-3 cm from the midline
Orientation
In the direction of that line; inter-electrode distance max. 20 mm, electrode size max. 10 mm along the fibres
Signal check
Forward flexion of the torso and return to midline.
Crosstalk from
iliocostalis and longissimus lie over the multifidus — surface recording does not separate them · quadratus lumborum · latissimus dorsi
MVC test
Prone on a bench, trunk extension (upper body lifted against resistance).
Fixation
Legs and pelvis fixed on the bench.
Resistance
Manual resistance or belt across the upper back, extension against it.
Skin prepared ImpedancekΩ Signal check ok MVC peakµV Note
Sources: SENIAM (Hermens 2000) · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=multifidus_l
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer

Muscle pages: M. Multifidus (left)

All 49 muscle protocols as a PDF — free
Print-ready for the lab or clinic: 77 pages of protocols (SENIAM + peer-reviewed), plus the SENIAM table, a placement checklist and a sensor comparison sheet as A4 sheets.