EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
26.10.2026
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Gluteus Medius
SENIAM
- Position
- 50% on line between iliac crest and greater trochanter
- Orientation
- Parallel to line iliac crest-greater trochanter
- Signal check
- Abduct the leg side-lying or standing sideways against a wall; single-leg stance; walking.
- Crosstalk from
- gluteus maximus · erector spinae
- MVC test
- Side-lying with fixed pelvis, or supine; hip abduction. Some subjects reach higher values standing.
- Fixation
- Pelvis fixed with a belt or manually.
- Resistance
- Manual resistance or belt against the lateral thigh, abduction against it.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: SENIAM (Hermens 2000) · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=gluteus_medius_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer