DE Open 3D Viewer
Choose muscles in the 3D viewer →

Up to 4 muscles per sheet: bookmark them in the 3D viewer and choose “Print session sheet” there.

EMG session sheet

Electrode positions, signal check and MVC test on one sheet

emgguide.de
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate

Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter

S1 M. Gluteus Maximus Gluteus Maximus · right · Hip SENIAM
M. Gluteus Maximus
Position
50% on line between sacrum and greater trochanter
Orientation
Along the line posterior superior iliac spine–middle of the posterior thigh
Signal check
Prone or standing (hands on the wall), extend the leg backwards; alternatively stair stepping, sit-to-stand, external rotation of the thigh.
Crosstalk from
usually not a problem per Criswell
MVC test
Prone, hip hyperextension of about 20° with slightly outward-rotated leg; test with extended and with flexed knee.
Fixation
Pelvis fixed on the bench.
Resistance
Manual resistance or belt against the back of the thigh, hip extension against it.
Skin prepared ImpedancekΩ Signal check ok MVC peakµV Note
Sources: SENIAM (Hermens 2000) · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=gluteus_maximus_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer

Muscle pages: M. Gluteus Maximus (right)

All 49 muscle protocols as a PDF — free