EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
25.10.2026
25.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Extensor Digitorum
Literature
- Position
- 50% on line from lateral epicondyle to the ulna
- Orientation
- Parallel to the forearm (dorsal)
- Signal check
- Extend the fingers.
- Crosstalk from
- extensor digiti minimi · extensor carpi ulnaris (a distal placement separates the finger extensors better from the wrist flexors)
- MVC test
- Seated or kneeling in front of a bench with the forearm resting on a stable support.
- Fixation
- Forearm fully supported; wrist free to work against the resistance.
- Resistance
- Manual resistance, a barbell or a cable/belt against the wrist or hand.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: Farina et al. 2015 · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=extensor_digitorum_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer