EMG session sheet
Electrode positions, signal check and MVC test on one sheet
emgguide.de
26.10.2026
26.10.2026
Date
Subject / ID
Examiner
Device · sampling rate
Recording set-up per Konrad 2005: Inter-electrode distance 2 cm (centre to centre) · Skin impedance: aim < 10 kΩ, up to 30 kΩ acceptable, above 50 kΩ prepare again · Band-pass 10–500 Hz · Sampling ≥ 1000 Hz · no notch filter
S1
M. Extensor Carpi Radialis Longus
Literature
- Position
- 30% on line from lateral epicondyle to Proc. styloideus radii
- Orientation
- Parallel to the radius
- Signal check
- Wrist extension and radial deviation.
- Crosstalk from
- brachioradialis · extensor digitorum
- MVC test
- Seated or kneeling in front of a bench with the forearm resting on a stable support.
- Fixation
- Forearm fully supported; wrist free to work against the resistance.
- Resistance
- Manual resistance, a barbell or a cable/belt against the wrist or hand.
Skin prepared
ImpedancekΩ
Signal check ok
MVC peakµV
Note
Sources: Riek & Carson 2000 · Signal check & crosstalk: Criswell 2011 · MVC test & set-up: Konrad 2005
Live on the 3D model: emgguide.de/?muscle=extensor_carpi_radialis_longus_r
Visualise the activation live: easyEMG · Educational reference, not a medical device. For use by trained persons following the manufacturer's instructions. emgguide.de/disclaimer