SENIAM (Hermens 2000)
SENIAMHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/trapeziusdescendens.htmlElectrode positions on emgguide.de are based on the official SENIAM recommendations (Hermens et al. 2000) for 26 muscle pairs, plus peer-reviewed literature for 16 further pairs not covered by the SENIAM catalogue. For the remaining 12 pairs without a specific publication, placement follows anatomical landmarks and established clinical practice. Together that is 54 muscle pairs, or 108 muscles counting left and right.
Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/trapeziusdescendens.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/trapeziustransversalis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/trapeziusascendens.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/deltoideusanterior.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/deltoideusmedius.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/deltoideusposterior.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/bicepsbrachii.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/tricepsbrachiilateralhead.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/tricepsbrachiilonghead.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/erectorspinaeiliocostalis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/erectorspinaelongissimus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/multifidus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/gluteusmaximus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/gluteusmedius.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/tensorfasciaelatae.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/quadricepsfemorisrectusfemoris.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/quadricepsfemorisvastuslateralis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/quadricepsfemorisvastusmedialis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/bicepsfemoris.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/semitendinosus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/gastrocnemiusmedialis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/gastrocnemiuslateralis.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/soleus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/tibialisanterior.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/peroneuslongus.htmlHermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361-74.
http://seniam.org/peroneusbrevis.htmlBoettcher CE, Ginn KA, Cathers I. Standard maximum isometric voluntary contraction tests for normalizing shoulder muscle EMG. J Orthop Res. 2008;26(12):1591-1597.
https://doi.org/10.1002/jor.20675Boettcher CE, Ginn KA, Cathers I. Standard maximum isometric voluntary contraction tests for normalizing shoulder muscle EMG. J Orthop Res. 2008;26(12):1591-1597.
https://pubmed.ncbi.nlm.nih.gov/18528827/Date S, Kurumadani H, Nakashima Y, Ishii Y, Ueda A, Kurauchi K, Sunagawa T. Brachialis muscle activity can be measured with surface electromyography: a comparative study using surface and fine-wire electrodes. Front Physiol. 2021;12:809422.
https://doi.org/10.3389/fphys.2021.809422Donnelly T, Routledge N, Seminati E, Metcalfe B. A method for locating surface electromyography electrodes on the flexor carpi ulnaris. J Electromyogr Kinesiol. 2025;82:103010.
https://doi.org/10.1016/j.jelekin.2025.103010Ekstrom RA, Donatelli RA, Soderberg GL. Surface electromyographic analysis of exercises for the trapezius and serratus anterior muscles. J Orthop Sports Phys Ther. 2003;33(5):247-258.
https://www.jospt.org/doi/10.2519/jospt.2003.33.5.247Elsais WM, Preece SJ, Jones RK, Herrington L. Could relative movement between the adductor muscles and the skin invalidate surface electromyography measurement? Monten J Sports Sci Med. 2020;9(2):21-26.
https://doi.org/10.26773/mjssm.200904Falla D, Dall'Alba P, Rainoldi A, Merletti R, Jull G. Location of innervation zones of sternocleidomastoid and scalene muscles - a basis for clinical and research electromyography applications. Clin Neurophysiol. 2002;113(1):57-63.
https://pubmed.ncbi.nlm.nih.gov/11801425/Farina D, Kallenberg LA, Holobar A. Extracting extensor digitorum communis activation patterns using high-density surface electromyography. Front Physiol. 2015;6:279.
https://doi.org/10.3389/fphys.2015.00279Green LA, McGuire J, Gabriel DA. Flexor carpi radialis surface electromyography electrode placement for evoked and voluntary measures. Muscle Nerve. 2015;52(5):818-25.
https://doi.org/10.1002/mus.24631Król H, Sobota G, Nawrat A. Effect of electrode position on EMG recording in pectoralis major. J Hum Kinet. 2007;17:105-112.
https://www.researchgate.net/publication/234002036Merlo A, Bo MC, Campanini I. Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review. Sensors (Basel). 2021;21(21):7322.
https://doi.org/10.3390/s21217322Ng JK-F, Kippers V, Richardson CA. Muscle fibre orientation of abdominal muscles and suggested surface EMG electrode positions. Electromyogr Clin Neurophysiol. 1998;38(1):51-58.
https://pubmed.ncbi.nlm.nih.gov/9532434/Riek S, Carson RG. A new technique for the selective recording of extensor carpi radialis longus and brevis EMG. J Electromyogr Kinesiol. 2000;10(4):249-57.
https://doi.org/10.1016/S1050-6411(00)00017-1